HOTEL SANTIKA
Location
​
Year
​
Client
​
Development
​
Foundation
Retaining Wall
Professional Services
​
​
​
Challenge and accomplishment
:
​
:
​
:
​
:
​
​
:​
​
:
​
:
​
​
​
​
:
Bukit Tinggi, West Sumatera​
​
2017
​
PT. Pesona Indonesia Mulia
Hotel (7 stories)
Basement (2 stories)
​
Bored Pile
​
Soldier Pile
Geotechnical consultancy
Soil investigation
Design of foundation and shoring system
Pile Testing with PDA Test
​
The design started in sloping ground with indication of moving ground. By protection using soldier piles for its basement excavation, GEC provides a system of stable foundation solution.

MASON PINE HOTEL EXTENSION
Location
​
Year
​
Client
​
Development
​
Foundation
Retaining Wall
Professional Services
​
:
​
:
​
:
​
:
​
​
:​
​
:
​
:
Kota Baru Parahyangan, West Java​
​
2016
​
PT. Gistama Intisemesta
Hotel (7 stories)
Podium (3 stories)
​
Bored Pile
​
Soldier Pile
Geotechnical consultancy
Design of foundation and shoring system

DE PAVILIJOEN HOTEL
Location
​
Year
​
Client
​
Development
Foundation
Retaining Wall
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
​
:
Bandung, West Java​
​
2014
​
PT. Perkasa Carista Estetika
1.550 m2 development area
Hotel tower (9 stories)
Podium (2 stories)
Basement (2 stories)
​
Shallow foundation
​
Soil nailing & secant pile
Geotechnical consultancy
Design of foundation and shoring system

HOLIDAY INN EXPRESS BARUNA
Location
​
Year
​
Client
​
Development
Foundation
Retaining Wall
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
​
:
Baruna, Bali​
​
2013
​
PT. Menara Perdana
Hotel (5 stories)
​
Bored Pile and Raft Foundation
​
Secant Pile
Geotechnical consultancy
Design of foundation and shoring system

​PULLMAN HOTEL @ VIMALA HILLS
Location
​
Year
​
Client
​
Development
Foundation
Retaining Wall
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
​
:
Ciawi, Bogor, West Java​
​
2013
​
PT. Putra Adhi Prima
10 ha development area
​
Driven Pile
​
Soil Nailing and shotcrete
Geotechnical consultancy
Soil investigation
Design of foundation and shoring system
Inclinometer monitoring
Supervision for geotechnical works

PULLMAN CITY CENTER BANDUNG
Location
​
Year
​
Client
​
Development
​
​
Foundation
​
Retaining Wall
​
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
​
:
Bandung, West Java​
​
2012
​
PT. Tritunggal Lestari Makmur
​
48.000m2 development area
1 hotel tower (13 stories)
Basement (2 stories)
​
Raft Foundation
​
Soldier Pile and Soil nailing
Geotechnical consultancy
Soil investigation
Design of foundation and shoring system

TUNE HOTEL SOLO
Location
​
Year
​
Client
​
Development
Foundation
​
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
Solo, Central Java​
​
2012
​
PT. Planet Merah Dua Belas
​
1 hotel tower (9 stories)
Basement (water tank + STP)
​
Driven Pile (Push in / Jack in Method)
Geotechnical consultancy
Soil investigation
Design of foundation and slope stability analysis

ASTON SENTUL RESORT & CONFERENCE CENTER
Location
​
Year
​
Client
​
Development
Foundation
​
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
Sentul, Bogor, West Java​
​
2011
​
PT. Sentul Damai Resort
​
+/- 5 ha development area
​
Bored Pile
Geotechnical consultancy
Soil investigation
Design of foundation and slope stability analysis

RAMADA SAKALA RESORT BALI
Location
​
Year
​
Client
​
Development
​
Foundation
​
Retaining Wall
​
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
​
:
Tanjung Benoa, Bali​
​
2011
​
PT. Total Bangun Persada
​
Beach Front
Lobby (4 stories + 1 level basement)
Pool Villa
Garden Restaurant
Condotel (4 stories + 1 level basement)
​
Driven Pile
​
Soldier Pile
Geotechnical consultancy
Design of foundation and shoring system

TUNE HOTEL MAKASSAR
Location
​
Year
​
Client
​
Development
​
Foundation
Retaining Wall
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
​
:
Makassar, South Sulawesi​
​
2011
​
PT. Planet Merah Empat
​
1 hotel tower (10 stories)
Basement (1 story)
​
Driven Pile (Push in / Jack in Method)
​
Sheetpile
Geotechnical consultancy
Soil investigation
Design of foundation and shoring system

TUNE HOTEL ARJUNA SURABAYA
Location
​
Year
​
Client
​
Development
​
Foundation
Retaining Wall
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
​
:
Surabaya, East Java​
​
2011
​
PT. Planet Merah Lima
​
1 hotel tower (7 stories)
Small Basement
​
Driven Pile (Push in / Jack in Method)
​
Spunpile
Geotechnical consultancy
Soil investigation
Design of foundation and shoring system

HOTEL PESONA ALAM CISARUA
Location
​
Year
​
Client
​
Development
Foundation
Professional Services
​
:
​
:
​
:
​
:
​
:​
​
:
Bogor, West Java​
​
2011
​
PT. Kusuma Anugrah Damai Sejahtera
5 blocks hotel (2-5 stories)
​
Bored Pile
Geotechnical consultancy
Design of foundation
Slope stability analysis

PADMA RESORT UBUD
Location
​
Year
​
Client
​
Development
​
​
Foundation
Retaining Wall
Professional Services
​
​
​
Challenge and accomplishment
:
​
:
​
:
​
:
​
:​
​
:
​
:
​
​
​
​
:
Gianyar, Bali​
​
2011
​
PT. Puri Zuqni
20.000m2 development area
Guest room building blocks (6 stories)
Resort Facilities
​
Shallow Foundation and Driven Pile
​
Soldier Pile and Soil Nailing
Geotechnical consultancy
Soil investigation
Design of foundation and shoring system
Inclinometer monitoring
​
Buildings and pools on slopes are typical challenges in Ubud area. GEC investigated and ensure the safety by sufficient investigation and monitoring slopes with inclinometers.

PADMA HOTEL BANDUNG
Location
​
Year
​
Client
​
​
Development
​
Foundation
Retaining Wall
Professional Services
​
​
​
Challenge and accomplishment
​
:
​
:
​
:
​
​
:
:​
​
:
​
:
​
​
​
​
:
Bandung, West Java​
​
2006
​
PT. Trigana Putra Mandiri
PT. Jaya Kusuma Sarana
Hotel (6 stories)
Wing Hotel (2 stories)
Entertainment Room
Park House
​
Bored Pile
​
Soldier Pile, Soil Nailing, and Shotcrete
Geotechnical consultancy
Soil investigation
Design of foundation and shoring system Supervision of geotechnical works
​
Difficult terrain condition where buildings have to be designed safely on steep slopes. Bored piles were selected for foundation system and slope protection has been successfully done.